5000 Volt
    COPPER CONDUCTOR CABLES




    System
    Number (1)
    Nominal Ampacity (2) Conductor MCM Cables
    Per Phase
    Dimensions
    H" X W" (3)
    Wt.
    Lbs./Ft.

    CB05000C0350-03
    CB05000C0500-03

    CB05000C0750-03
    CB05000C0500-06

    CB05000C0500-06
    CB05000C0750-06

    CB05000C0750-09
    CB05000C0750-09

    CB05000C0500-12
    CB05000C0750-12

    CB05000C0500-18
    CB05000C0750-18

    CB05000C1000-18
    CB05000C1250-18


    400
    600

    800
    1000

    1200
    1600

    1800
    2000

    2500
    3000

    3500
    4000

    5000
    6000

    350
    500

    750
    500

    500
    750

    750
    750

    500
    750

    500
    750

    1000
    1250

    1
    1

    1
    2

    2
    2

    3
    3

    4
    4

    6
    6

    6
    6

    8 X 12
    8 X 12

    8 X 12
    8 X 12

    8 X 12
    8 X 12

    12 X 12
    12 X 12

    8 X 24
    8 X 24

    10 X 24
    12 X 24

    12 X 24
    14 X 24 *

    9
    11

    14
    17

    17
    23

    31
    31

    31
    40

    42
    58

    72
    97

    Notes:
    (1)  Systems shown are three phase. Other systems available include three phase with neutral, single phase and D.C.
    (2)  Based on ICEA Standard P-46-426 with conductor temperature of 90°C max. and 40°C ambient, other conductor and ambient temperature designs available.
    (3)  Inside width, for overall width add 2" * Check factory for fitting dimensions.



    5000 Volt
    ALUMINUM CONDUCTOR CABLES





    System
    Number (1)
    Nominal Ampacity (2) Conductor MCM Cables
    Per Phase
    Dimensions
    H" X W" (3)
    Wt.
    Lbs./Ft.

    CB05000A0500-03
    CB05000A1000-03

    CB05000A0500-06
    CB05000A0750-06

    CB05000A1000-06
    CB05000A1000-09

    CB05000A0750-12
    CB05000A0750-12

    CB05000A1000-12
    CB05000A0750-18

    CB05000A1000-18
    CB05000A1250-18

    CB05000A1500-18
    CB05000A2000-18


    400
    600

    800
    1000

    1200
    1600

    1800
    2000

    2500
    3000

    3500
    4000

    5000
    6000

    500
    1000

    500
    750

    1000
    1000

    750
    750

    1000
    750

    1000
    1250

    1500
    2000

    1
    1

    2
    2

    2
    3

    4
    4

    4
    6

    6
    6

    6
    6

    8 X 12
    8 X 12

    8 X 12
    8 X 12

    8 X 12
    12 X 12

    8 X 24
    8 X 24

    8 X 24
    10 X 24

    12 X 24
    12 X 24

    14 X 30 *
    14 X 30 *

    8
    10

    11
    12

    14
    17

    21
    21

    25
    28

    33
    49

    55
    65

    Notes:
    (1)  Systems shown are three phase. Other systems available include three phase with neutral, single phase and D.C.
    (2)  Based on ICEA Standard P-46-426 with conductor temperature of 90°C max. and 40°C ambient, other conductor and ambient temperature designs available.
    (3)  Inside width, for overall width add 2" (51) to inside width. * Check factory for fitting dimensions



    Please click here to open a Cable Bus System Quotation Form